Notice: Undefined index: system in /WAS/WebDir/cdbio/_include/class.useragent.php on line 207

Notice: Trying to access array offset on value of type null in /WAS/WebDir/cdbio/_include/class.useragent.php on line 207

Notice: Undefined index: system in /WAS/WebDir/cdbio/_include/class.useragent.php on line 208

Notice: Trying to access array offset on value of type null in /WAS/WebDir/cdbio/_include/class.useragent.php on line 208

Notice: Undefined index: system in /WAS/WebDir/cdbio/_include/class.useragent.php on line 208

Notice: Trying to access array offset on value of type null in /WAS/WebDir/cdbio/_include/class.useragent.php on line 208

Notice: Undefined index: system in /WAS/WebDir/cdbio/_include/class.useragent.php on line 214

Notice: Trying to access array offset on value of type null in /WAS/WebDir/cdbio/_include/class.useragent.php on line 214

Notice: Undefined index: system in /WAS/WebDir/cdbio/_include/class.useragent.php on line 257

Notice: Trying to access array offset on value of type null in /WAS/WebDir/cdbio/_include/class.useragent.php on line 257

Notice: Undefined index: system in /WAS/WebDir/cdbio/_include/class.useragent.php on line 262

Notice: Trying to access array offset on value of type null in /WAS/WebDir/cdbio/_include/class.useragent.php on line 262
씨디바이오 | CDBIO
Product & Service

VOCs Bioscopic Analyzer

< VOCs Bioscopic Analyzer(Personal) >
< Molecular Diagnostic App >

Insert the VOC Biosensing Kit into the Bioscopic Analyzer

Monitoring the presence of disease, progression status, development of therapeutic agents, and administration effects through our analysis algorithm applied with ‘principal component analysis’ and ‘multivariate analysis’ based on the current value measured by the molecular sensor loaded with lithium endohedral fullerene (Li⁺@C60) and supramolecular dye.

Send analysis results and data to VOC Bioscopic app

※ Details of the composition are not shown for confidentiality.
H/W
  • Structured with a VOC-kit mount, (light) energy supply, sensor control, signal standardization, and control
  • VOC-kit mount: VOC-kit binding structure, temperature control (constant)
  • (Light) energy supply: Supplies dye operation energy, composed of LEDs with specific wavelengths
  • Sensor control: Controls the operation connected with the sensor mounted on the VOC kit
  • Signal standardization: Amplifies and processes the VOC signal detected and measured through the sensor
  • Control: Controls VOC system operation
S/W
  • VOC Detection Algorithm: Algorithm to detect VOC by controlling sensor operation
  • VOC Analysis Algorithm: Algorithm to analyze VOC measurement data (principal component analysis, etc.)
  • VCC Diagnosis Algorithm: Algorithm to provide judgment data for disease contraction based on the VOC analysis data
  • Operation algorithm for VOC Biosensing Kit and VOC Bioscopic Analyzer
  • DB Operation Algorithm